{"product_id":"3500w-70a-24v-epro-combi-inverter-charger","title":"3500W\/70A 24V ePRO Combi Inverter Charger","description":"\u003cp\u003eThe main task of the ePRO Combi Inverter Charger is to act as an uninterruptible AC power supply (UPS). In case of a grid\/generator failure or disconnection, the ePRO Combi immediately stops charging the battery, releases the AC transfer switch and activates the inverter which takes over the supply to the connected loads. All this is achieved so fast, that even very critical loads like computers will continue to operate without any problems. In case the grid\/generator is reconnected again and the voltage and frequency are within acceptable limits, the ePRO Combi activates the AC transfer switch and battery charger again, while deactivating the inverter. The connected loads are now supplied again by the grid\/generator without any interruption. Available in 12v and 24v models and ranging in sizes from 1600-3500w inverter output and 35-120A charger output, the ePRO Combi has a unit to suit nearly any application.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cp\u003eThe main task of the ePRO Combi Inverter Charger is to act as an uninterruptible AC power supply (UPS). In case of a grid\/generator failure or disconnection, the ePRO Combi immediately stops charging the battery, releases the AC transfer switch and activates the inverter which takes over the supply to the connected loads. All this is achieved so fast, that even very critical loads like computers will continue to operate without any problems. In case the grid\/generator is reconnected again and the voltage and frequency are within acceptable limits, the ePRO Combi activates the AC transfer switch and battery charger again, while deactivating the inverter. The connected loads are now supplied again by the grid\/generator without any interruption.\u003c\/p\u003e\u003cp\u003eAvailable in 12v, 24v or 48v models and ranging in sizes from 1600-3500w inverter output and 35-120A charger output, the ePRO Combi has a unit to suit nearly any application.\u003c\/p\u003e\u003ch4\u003eAdditionally, the ePRO Inverter Charger offers features like :\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAC Input Power Boost,\u003c\/strong\u003e which temporarily assists weak AC input sources when the connected load needs more power than available from the grid or generator.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAC Input Current Limit,\u003c\/strong\u003e which limits the maximum current consumed from the AC input source by the ePRO Combi. This limit is user adjustable.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Factor Corrected AC Input,\u003c\/strong\u003e which optimizes energy efficiency and makes sure that the maximum amount of charging current is available from your AC source.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntelligent 4-stage charge programs,\u003c\/strong\u003e user programmable to fit any battery type.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFully programmable inverter, transfer switch and battery charger parameters,\u003c\/strong\u003e using the Dashboard for Windows software.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProgrammable alarm relay,\u003c\/strong\u003e for optimal control of external devices like generator starting or selective load disconnection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFreely assignable trigger input,\u003c\/strong\u003e which allows the user to control the ePRO Combi by external events.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTemperature controlled fans,\u003c\/strong\u003e to guarantee silent operation under less than full load conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTemperature compensated battery charging,\u003c\/strong\u003e using the standard supplied battery temperature sensor for maximum battery lifetimes.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eWhen installation space is at a premium, but maximum performance is required then look no further than the ePRO Combi range. With so many internal features the ePRO Combi will provide you with all the requirements for on-board power along with:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAC Input Power Boost\u003c\/strong\u003e – The ePRO Combi is capable of temporarily assisting weak AC input sources when more power is needed than available (i.e. from small generators). This is beneficial when larger loads than both the generator or the inverter on their own could support; so let the ePRO Combi combine both of the AC sources for maximum load support capability.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAC Input Current Limit\u003c\/strong\u003e – For those times when you have limited AC supply (i.e. portable generators), you can set the ePRO Combi to only charge at a maximum rate.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAlarm Output Relays\u003c\/strong\u003e – Providing full configuration options for the alarm contacts PLUS convert external trigger commands into a number of ePRO Combi status changes.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAlso available\u003c\/strong\u003e on the larger 2000-3500w Combi’s are two fully configurable 16A 230v alarm relay outputs for controlling large AC loads like air conditioning. Along with two unique trigger inputs, it gives the end user virtually unparalleled control of their Enerdrive ePRO “Power Station”.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eUniversal Remote Control\u003c\/h4\u003e\u003ch4\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0953\/8237\/2639\/files\/universal-remote-page-image-277x158.png?v=1789531664\"\u003e\u003c\/h4\u003e\u003cp\u003eThe Universal Remote Control (URC) can be used to remotely readout all available parameters from your ePRO inverter\/charger Combi, like charging current, output voltage, charge stage etc. It is also possible to put the Combi in standby mode or to wake it up again, besides being able to control the maximum charge current and the maximum AC input current. All information is shown on a clear white backlit graphical display. This kit comes with mounting screws and a 3 meter interface cable (standard cat5 patch cable). The URC automatically recognizes to which type of equipment it is connected.\u003c\/p\u003e\u003ch4\u003eApplications\u003c\/h4\u003e\u003cp\u003e\u003cstrong\u003eRecreational vehicles\u003c\/strong\u003e – With a very small size footprint for power output, the ePRO Combi is the perfect solution for tight installations.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSolar Power Systems\u003c\/strong\u003e – Suitable for small back up sites that require variable control capabilities with the innovative Trigger Switches.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eIndustrial Systems\u003c\/strong\u003e – Any small commercial application can be configured to use the ePRO Combi as a smart UPS system again using the Trigger Switches.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eCommercial work vehicles\u003c\/strong\u003e – Provide ultra clean AC power for sensitive equipment.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eMarine Systems\u003c\/strong\u003e – Great charging capabilities from a small unit.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ch4\u003eePRO Combi Inverter Charger Specifications\u003c\/h4\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003cth\u003e1600W\/60A 12V ePRO Combi Inverter Charger\u003c\/th\u003e\n\u003cth\u003e1800W\/35A 24V ePRO Combi Inverter Charger\u003c\/th\u003e\n\u003cth\u003e3000W\/120A 12V ePRO Combi Inverter Charger\u003c\/th\u003e\n\u003cth\u003e3500W\/70A 24V ePRO Combi Inverter Charger\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003eEPC-1600-12\u003c\/td\u003e\n\u003ctd\u003eEPC-1800-24\u003c\/td\u003e\n\u003ctd\u003eEPC-3000-12\u003c\/td\u003e\n\u003ctd\u003eEPC-3500-24\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput power (VA)\u003c\/td\u003e\n\u003ctd\u003e1600VA\u003c\/td\u003e\n\u003ctd\u003e1800VA\u003c\/td\u003e\n\u003ctd\u003e3000VA\u003c\/td\u003e\n\u003ctd\u003e3500VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput power (1) Pnom\u003c\/td\u003e\n\u003ctd\u003e1300W\u003c\/td\u003e\n\u003ctd\u003e1400W\u003c\/td\u003e\n\u003ctd\u003e2600W\u003c\/td\u003e\n\u003ctd\u003e2800W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eP10minutes\u003c\/td\u003e\n\u003ctd\u003e1600W\u003c\/td\u003e\n\u003ctd\u003e1800W\u003c\/td\u003e\n\u003ctd\u003e3200W\u003c\/td\u003e\n\u003ctd\u003e3800W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePsurge\u003c\/td\u003e\n\u003ctd\u003e2500W\u003c\/td\u003e\n\u003ctd\u003e3000W\u003c\/td\u003e\n\u003ctd\u003e5000W\u003c\/td\u003e\n\u003ctd\u003e6500W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput voltage \/ frequency\u003c\/td\u003e\n\u003ctd\u003e230 Vac ± 2% \/ 50 Hz ± 0.05%\u003c\/td\u003e\n\u003ctd\u003e230 Vac ± 2% \/ 50 Hz ± 0.05%\u003c\/td\u003e\n\u003ctd\u003e230 Vac ± 2% \/ 50 Hz ± 0.05%\u003c\/td\u003e\n\u003ctd\u003e230 Vac ± 2% \/ 50 Hz ± 0.05%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput waveform\u003c\/td\u003e\n\u003ctd\u003eTrue Sine Wave (THD \u0026lt; 5% 1 @ Pnom)\u003c\/td\u003e\n\u003ctd\u003eTrue Sine Wave (THD \u0026lt; 5% 1 @ Pnom)\u003c\/td\u003e\n\u003ctd\u003eTrue Sine Wave (THD \u0026lt; 5% 1 @ Pnom)\u003c\/td\u003e\n\u003ctd\u003eTrue Sine Wave (THD \u0026lt; 5% 1 @ Pnom)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput voltage (± 3% tolerance): Nominal\u003c\/td\u003e\n\u003ctd\u003e12V\u003c\/td\u003e\n\u003ctd\u003e24V\u003c\/td\u003e\n\u003ctd\u003e12V\u003c\/td\u003e\n\u003ctd\u003e24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e10.5 (2) – 16 Vdc\u003c\/td\u003e\n\u003ctd\u003e21 (2) – 32 Vdc\u003c\/td\u003e\n\u003ctd\u003e10.5 (2) – 16 Vdc\u003c\/td\u003e\n\u003ctd\u003e21 (2) – 32 Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum efficiency\u003c\/td\u003e\n\u003ctd\u003e92%\u003c\/td\u003e\n\u003ctd\u003e94%\u003c\/td\u003e\n\u003ctd\u003e92%\u003c\/td\u003e\n\u003ctd\u003e93%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNo load power consumption (2) [ASB]\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;10 W [2.0 W]\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;12 W [2.0 W]\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;20 W [3.5 W]\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;20 W [4.0 W]\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eCharger stage\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC input voltage\u003c\/td\u003e\n\u003ctd\u003e185 – 270 Vac \/ 45 – 65 Hz \/ PF \u0026gt; 0.95\u003c\/td\u003e\n\u003ctd\u003e185 – 270 Vac \/ 45 – 65 Hz \/ PF \u0026gt; 0.95\u003c\/td\u003e\n\u003ctd\u003e185 – 270 Vac \/ 45 – 65 Hz \/ PF \u0026gt; 0.95\u003c\/td\u003e\n\u003ctd\u003e185 – 270 Vac \/ 45 – 65 Hz \/ PF \u0026gt; 0.95\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum continuous charging current (4)\u003c\/td\u003e\n\u003ctd\u003e60A\u003c\/td\u003e\n\u003ctd\u003e35A\u003c\/td\u003e\n\u003ctd\u003e120A\u003c\/td\u003e\n\u003ctd\u003e70A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard charge voltage (bulk \/ float @ 25°C)\u003c\/td\u003e\n\u003ctd\u003e14.3V \/ 13.3V (programmable)\u003c\/td\u003e\n\u003ctd\u003e28.6V \/ 26.6V (programmable)\u003c\/td\u003e\n\u003ctd\u003e14.3V \/ 13.3V (programmable)\u003c\/td\u003e\n\u003ctd\u003e28.6V \/ 26.6V (programmable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCharge algorithm\u003c\/td\u003e\n\u003ctd\u003eIUoUoP, intelligent 4-stage, temperature compensated (programmable)\u003c\/td\u003e\n\u003ctd\u003eIUoUoP, intelligent 4-stage, temperature compensated (programmable)\u003c\/td\u003e\n\u003ctd\u003eIUoUoP, intelligent 4-stage, temperature compensated (programmable)\u003c\/td\u003e\n\u003ctd\u003eIUoUoP, intelligent 4-stage, temperature compensated (programmable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eAC Transfer Switch\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum continuous current\u003c\/td\u003e\n\u003ctd\u003e16 Ams\u003c\/td\u003e\n\u003ctd\u003e16 Ams\u003c\/td\u003e\n\u003ctd\u003e30 Ams\u003c\/td\u003e\n\u003ctd\u003e30 Ams\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransfer time (typical)\u003c\/td\u003e\n\u003ctd\u003e0 ms (inverter to mains) \/ \u0026lt;5 ms (mains to inverter)\u003c\/td\u003e\n\u003ctd\u003e0 ms (inverter to mains) \/ \u0026lt;5 ms (mains to inverter)\u003c\/td\u003e\n\u003ctd\u003e0 ms (inverter to mains) \/ \u0026lt;5 ms (mains to inverter)\u003c\/td\u003e\n\u003ctd\u003e0 ms (inverter to mains) \/ \u0026lt;5 ms (mains to inverter)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eGeneral\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eePROLink enabled\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtections\u003c\/td\u003e\n\u003ctd\u003ehigh\/low battery voltage, high temperature, overload, short circuit, high ripple voltage and low AC input voltage\u003c\/td\u003e\n\u003ctd\u003ehigh\/low battery voltage, high temperature, overload, short circuit, high ripple voltage and low AC input voltage\u003c\/td\u003e\n\u003ctd\u003ehigh\/low battery voltage, high temperature, overload, short circuit, high ripple voltage and low AC input voltage\u003c\/td\u003e\n\u003ctd\u003ehigh\/low battery voltage, high temperature, overload, short circuit, high ripple voltage and low AC input voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC connections\u003c\/td\u003e\n\u003ctd\u003eTwo wires, length 1.5 meters, 50mm2 - M8 bolt terminals\u003c\/td\u003e\n\u003ctd\u003eTwo wires, length 1.5 meters, 50mm2 - M8 bolt terminals\u003c\/td\u003e\n\u003ctd\u003eTwo wires, length 1.5 meters, 120mm2 - M10 bolt terminals\u003c\/td\u003e\n\u003ctd\u003eTwo wires, length 1.5 meters, 120mm2 - M10 bolt terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC connections\u003c\/td\u003e\n\u003ctd\u003eScrew terminals\u003c\/td\u003e\n\u003ctd\u003eScrew terminals\u003c\/td\u003e\n\u003ctd\u003eScrew terminals\u003c\/td\u003e\n\u003ctd\u003eScrew terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure body size\u003c\/td\u003e\n\u003ctd\u003e351 x 210 x 114mm\u003c\/td\u003e\n\u003ctd\u003e351 x 210 x 114mm\u003c\/td\u003e\n\u003ctd\u003e370 x 431 x 132mm\u003c\/td\u003e\n\u003ctd\u003e370 x 431 x 132mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal weight\u003c\/td\u003e\n\u003ctd\u003e10.7 Kg\u003c\/td\u003e\n\u003ctd\u003e10.7 Kg\u003c\/td\u003e\n\u003ctd\u003e19.0 Kg\u003c\/td\u003e\n\u003ctd\u003e19.0 Kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection class \/ operating temp. \/ storage temp.\u003c\/td\u003e\n\u003ctd\u003eIP21 \/ -20°C.. +50°C \/ -40°C.. +80°C (humidity max. 95% non-condensing)\u003c\/td\u003e\n\u003ctd\u003eIP21 \/ -20°C.. +50°C \/ -40°C.. +80°C (humidity max. 95% non-condensing)\u003c\/td\u003e\n\u003ctd\u003eIP21 \/ -20°C.. +50°C \/ -40°C.. +80°C (humidity max. 95% non-condensing)\u003c\/td\u003e\n\u003ctd\u003eIP21 \/ -20°C.. +50°C \/ -40°C.. +80°C (humidity max. 95% non-condensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandards\u003c\/td\u003e\n\u003ctd\u003eComplies with IEC 60335-2-29 including Australian deviations.\u003c\/td\u003e\n\u003ctd\u003eComplies with IEC 60335-2-29 including Australian deviations.\u003c\/td\u003e\n\u003ctd\u003eComplies with IEC 60335-2-29 including Australian deviations.\u003c\/td\u003e\n\u003ctd\u003eComplies with IEC 60335-2-29 including Australian deviations.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003cp\u003eNote: Specifications subject to change without notice.\u003c\/p\u003e\u003col\u003e\n\u003cli\u003eMeasured with resistive load at 25°C ambient. Power ratings are subject to a tolerance of 10% and are decreasing as temperature rises with a rate of approx. 1.2%\/°C starting from 25°C. Pnom is a typical value, measured using battery capacities of 200 Ah @ 12 V and 100 Ah @ 24V\u003c\/li\u003e\n\u003cli\u003eUndervoltage limit is dynamic. This limit decreases with increasing load to compensate the voltage drop across cables and connections.\u003c\/li\u003e\n\u003cli\u003eMeasured at nominal input voltage and 25°C.\u003c\/li\u003e\n\u003cli\u003eAt high ambient temperatures, maximum output current shall be reduced automatically.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch3\u003eAccessories\u003c\/h3\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eEnerdrive Part #\u003c\/th\u003e\n\u003cth\u003eDescription\u003c\/th\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e5095500\u003c\/td\u003e\n\u003ctd\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0953\/8237\/2639\/files\/epro-combi-uni-remote-inc-cable-450-277x277_70d207d8-df43-4509-84e1-15b856ed327f.jpg?v=1789531680\"\u003e\u003c\/td\u003e\n\u003ctd\u003eUniversal Remote Control and Cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5092120\u003c\/td\u003e\n\u003ctd\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0953\/8237\/2639\/files\/epro-combi-link_b1c4ac4b-cc88-48db-972d-4dbd011dcfa2.jpg?v=1789531680\"\u003e\u003c\/td\u003e\n\u003ctd\u003eePRO Link cable to connect to the ePRO Universal Remote Control or to a Windows device\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5092120\u003c\/td\u003e\n\u003ctd\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0953\/8237\/2639\/files\/tbs-combi-temp-sensor_061d853f-0fbe-42bc-98b6-6f3fc0035049.jpg?v=1789531680\"\u003e\u003c\/td\u003e\n\u003ctd\u003eTemperature Sensor (Included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5055630\u003c\/td\u003e\n\u003ctd\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0953\/8237\/2639\/files\/tbs_product_table_aoe-e1410999603854-150x150-2.jpg?v=1789531680\"\u003e\u003c\/td\u003e\n\u003ctd\u003eTBS Alarm expander board to suit ePro—expands alarm relays from 1 to 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003cp\u003eNote: Specifications subject to change without notice.\u003c\/p\u003e\n\u003ch3\u003eDownloads\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0953\/8237\/2639\/files\/ePRO-EPC1600-3500-Manual_rev2_f2c7f5d8-c98b-467a-8d8e-3b70dcab5525.pdf?v=1789531235\" rel=\"noopener\" target=\"_blank\"\u003eePRO Combi 1600 to 3500 User Manual\u003c\/a\u003e (426kb)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0953\/8237\/2639\/files\/EPC2000-3500-Installation-Guide-Rev2.pdf?v=1789531236\" rel=\"noopener\" target=\"_blank\"\u003eePRO Combi 2000 – 3500 Installation Guide\u003c\/a\u003e (1.2mb)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0953\/8237\/2639\/files\/ePRO-Combi-URC-UserManual_b0c3a732-8131-4648-8aba-9f761871810c.pdf?v=1789531250\" rel=\"noopener\" target=\"_blank\"\u003eUniversal Remote Control Owner’s Manual\u003c\/a\u003e (153kb)\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0953\/8237\/2639\/files\/Enerdrive-ePRO-Combi-Brochure.pdf?v=1789531200\" rel=\"noopener\" target=\"_blank\"\u003eePRO Combi Sales Brochure\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch5\u003eAccessory Downloads\u003c\/h5\u003e\u003cul\u003e\u003cli\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0953\/8237\/2639\/files\/TBS_Alarm_Output_Expander_Kit_rev01endfs.pdf?v=1789531251\" rel=\"noopener\" target=\"_blank\"\u003eTBS Alarm Output Expander Kit Guide\u003c\/a\u003e (57kb)\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch3\u003eUnder the Bonnet\u003c\/h3\u003e\u003ch4\u003eEnerdrive Offers A New Innovative Trigger-Action Feature For The ePRO Combi Inverter \/ Charger Series\u003c\/h4\u003e\u003cp\u003eAdd virtually unlimited control to your power system. The Trigger-action feature enables you to assign certain events (triggers) to user defined actions. You can for example configure the ePRO Combi to perform an action when a certain voltage, current or temperature level is reached, or perform an action when an external switch is closed or opened. This offers great flexibility and may in some cases avoid the need to invest in additional external hardware.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eA few practical examples are :\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0953\/8237\/2639\/files\/epro-combi-wiring-dia-635-300x230.jpg?v=1789531664\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0953\/8237\/2639\/files\/epro-combi-wiring-dia-635-300x230.jpg?v=1789531664\"\u003e\u003c\/a\u003e\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eDisable inverter mode using an external switch\u003c\/li\u003e\n\u003cli\u003eActivate a relay when the charger enters float mode\u003c\/li\u003e\n\u003cli\u003eStop charging using an external switch (i.e. from external BMS)\u003c\/li\u003e\n\u003cli\u003eTurn off an AC load when the inverter is overloaded\u003c\/li\u003e\n\u003cli\u003eOnly activate the transfer relay when the battery is almost empty\u003c\/li\u003e\n\u003cli\u003eTurn the AC Input boost function on or off depending on generator or mains supply (recommended so that the smart boost function does not run while connected to mains AC).\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e*Programming kit required for setup of triggers; or speak to Enerdrive at time of ordering.\u003c\/p\u003e\u003ch4\u003e\n\u003cstrong\u003eDashboard\u003c\/strong\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0953\/8237\/2639\/files\/epro-combi-dashboard-screen-shots-450.jpg?v=1789532207\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0953\/8237\/2639\/files\/epro-combi-dashboard-screen-shots-450-300x300.jpg?v=1789531680\"\u003e\u003c\/a\u003e\n\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eConfigure and readout your ePROLink enabled devices\u003c\/li\u003e\n\u003cli\u003eSupports multiple Enerdrive ePRO devices\u003c\/li\u003e\n\u003cli\u003eCheck all settings, status and history data with just the click of a button\u003c\/li\u003e\n\u003cli\u003eUse the advanced data recording wizard to log all available parameters\u003c\/li\u003e\n\u003cli\u003eOutput logged data to Microsoft Excel for further analysis\u003c\/li\u003e\n\u003cli\u003eOpen individual readout\/control panels for each device with real time parameter info\u003c\/li\u003e\n\u003cli\u003eCreate custom charge programs\u003c\/li\u003e\n\u003cli\u003eRename your device (i.e. “Starter battery”, “Accessory bank charger”)\u003c\/li\u003e\n\u003cli\u003eMany new features will be added periodically\u003c\/li\u003e\n\u003cli\u003eWill be supplied along with each communication kit (USB or RS232)\u003c\/li\u003e\n\u003cli\u003eWindows XP, Vista and Windows 7 compatible\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eApplications\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eTool for installation and service engineers\u003c\/li\u003e\n\u003cli\u003eLarge screen real-time monitoring\u003c\/li\u003e\n\u003cli\u003eBattery analysis\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Dometic","offers":[{"title":"Default Title","offer_id":52794697613599,"sku":"EPC-3500-24","price":4542.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/8237\/2639\/files\/SMP_1540.jpg?v=1789528106","url":"https:\/\/www.enerdrive.com.au\/products\/3500w-70a-24v-epro-combi-inverter-charger","provider":"Dometic Mobile Power APAC","version":"1.0","type":"link"}