{"title":"Alternators \u0026 Regulators","description":null,"products":[{"product_id":"balmar-duo-charge-ddc-12-24-regulator","title":"Balmar Duo Charge DDC-12\/24 Regulator","description":"\u003cp\u003eThe Digital Duo Charge (DDC-12\/24) provides a “hands off” solution for charging two battery banks without the use of problematic isolators or manual battery switches. During charging the DDC-12\/24 monitors voltage at the house battery. When voltage exceeds the set minimum (typically 13.2V in a 12V system and 26.4V in a 24V system) the DDC-12\/24 automatically engages, providing up to 30A charge current to the starting battery. When no charge source is present, the DDC-12\/24 separates the batteries so the starting battery won’t be accidentally discharged into the house battery. An optional solenoid control enables higher start battery charging output when required.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eDigital Duo Charge: DDC-12\/24\u003c\/strong\u003e\u003cbr\u003e\u003cem\u003e\u003cstrong\u003eMulti Bank Charging\u003c\/strong\u003e\u003c\/em\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eThe DDC is a Solid-State Battery Combiner\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eControl Voltage and Current between House and Start Batteries\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eEliminates the Need for an Isolator, Relay or Manually Operated Battery Switch\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eUsed in Concert with Max Charge or ARS-5 Regulators\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eCan also be Employed without a Balmar Regulator\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eWorks in Both 12V and 24V Applications\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eHouse and Start Batteries can be different technologies\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eStart Battery Temperature Sensing Available with the MC-TS-B Sensor Cable\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e4 Battery Programs Supported for the Start Battery:\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e Standard Flooded, Deep Cycle Flooded, AGM and Gel Cell\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eThe \u003cstrong\u003eDigital Duo Charge\u003c\/strong\u003e (DDC-12\/24) provides a “hands off” solution for charging two battery banks without the use of problematic isolators or manual battery switches. During charging the DDC-12\/24 monitors voltage at the house battery. When voltage exceeds the set minimum (typically 13.2V in a 12V system and 26.4V in a 24V system) the DDC-12\/24 automatically engages, providing up to 30A charge current to the starting battery.\u003c\/p\u003e\u003cp\u003eWhen no charge source is present, the DDC-12\/24 separates the batteries so the starting battery won’t be accidentally discharged into the house battery. An optional solenoid control enables higher start battery charging output when required.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSKU\u003c\/th\u003e\n\u003cth\u003eB-DDC-1224\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\u003ctr\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eDigital Duo Charge, 12\/24v, w\/Wires\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003c\/table\u003e\u003cp\u003eAlternator Regulators: Temperature Sensors\u003c\/p\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSKU\u003c\/th\u003e\n\u003cth\u003eB-MC-TS-A\u003c\/th\u003e\n\u003cth\u003eB-MC-TS-B\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\u003ctr\u003e\n\u003ctd\u003eLength\u003c\/td\u003e\n\u003ctd\u003eBalmar Alternator Temperature Sensor – 135cm long\u003c\/td\u003e\n\u003ctd\u003eBalmar Battery Temperature Sensor – 6m long\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eDownloads\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0953\/8237\/2639\/files\/Balmar-Duo-Charge-Manual.pdf?v=1789531319\" rel=\"noopener\" target=\"_blank\"\u003eBalmar Digital Duo Charge Manual\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/balmar.net\/balmar-catalog\/\" rel=\"noopener\" target=\"_blank\"\u003eBalmar 2020 Catalogue\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Balmar","offers":[{"title":"Default Title","offer_id":52794682016031,"sku":"B-DDC-1224","price":619.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/8237\/2639\/files\/BAL.DDC-1224_1200x1200_d98a07b2-f2bc-48be-98ef-2e74cd6354ae.jpg?v=1789528219"},{"product_id":"balmar-ars-5-regulator","title":"Balmar ARS-5 Regulator","description":"\u003cp\u003eThe Balmar ARS-5 provides precise voltage control for Balmar high-output 12-volt alternators and other externally regulated P-type (positive field) alternators, the ARS-5 features user selectable programs for the following battery types: Deep cycle flooded, gel, AGM and spiral wound (Optima) batteries. In addition, the regulator features a universal default (UFP) program that’s safe for most battery types.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eARS-5 Voltage Regulator\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e5 Selectable Programs for Marine Batteries\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e9 Amp Maximum Field Current\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eAppropriate for 6-Series Alternators (150A and below)\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eSingle Engine, Single Alternator Applications Only\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eAll the Same Programming Functions as the MC-614\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eThe Balmar ARS-5 Regular has simplified programming and a bright, easy-to-read 3-digit LED display make the ARS-5 the easiest multi-stage regulator to install and use. Selectable presets for five battery programs, including gel, AGM, Optima, deep-cycle and standard flooded, ensure proper time and voltage control.\u003c\/p\u003e\u003cp\u003eBelt Load Manager eliminates belt wear worries. Single alternator control only. ARS-5-H includes 54″ harness. Alternator and battery temperature sensing with optional temperature sensors. For P-type alternators. One year limited warranty.\u003c\/p\u003e\u003cul\u003e\u003cli\u003eFor 12-volt charging systems\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSKU\u003c\/th\u003e\n\u003cth\u003eB-ARS-5-H\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\u003ctr\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRegulator, ARS Multi-Stage, 12v, w\/Harness (P Type)\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eDownloads\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0953\/8237\/2639\/files\/Balmar-ARS-5-Manual.pdf?v=1789531319\" rel=\"noopener\" target=\"_blank\"\u003eBalmar ARS-5 Regulator Manual\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/balmar.net\/balmar-catalog\/\" rel=\"noopener\" target=\"_blank\"\u003eBalmar 2020 Catalogue\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Balmar","offers":[{"title":"Default Title","offer_id":52794682048799,"sku":"B-ARS-5-HC","price":660.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/8237\/2639\/files\/Balmar-ARS-5-1200x1200-1.jpg?v=1789528218"},{"product_id":"balmar-centerfielder-ii","title":"Balmar Centerfielder II","description":"\u003cp\u003eThe Centerfielder II (CFII-12\/24) balances twin engine charging systems by monitoring the port and starboard voltage regulators. When both alternators and regulators are working, the Centerfielder II automatically designates the starboard regulator as dominant for both alternators – making it possible to charge a single house battery bank with the combined output of both alternators.\u003c\/p\u003e\u003cp\u003eThe Centerfielder II eliminates the “yo-yo effect” of two regulators repeatedly turning on and off as the battery approaches target voltage because the two systems are not working in concert. Useful in applications like multihulls and powerboats with twin propulsion motors, the Centerfielder II acts like a referee, ensuring that both port and starboard charging systems work together, rather than compete, to keep a large house battery efficiently charged.\u003c\/p\u003e\u003cp\u003eThe Centerfielder II is designed to work specifically with MC-614 and MC-624 voltage regulators.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cp\u003eThe Centerfielder II (CFII-12\/24) balances twin engine charging systems by monitoring the port and starboard voltage regulators. When both alternators and regulators are working, the Centerfielder II automatically designates the starboard regulator as dominant for both alternators – making it possible to charge a single house battery bank with the combined output of both alternators.\u003c\/p\u003e\u003cp\u003eThe Centerfielder II eliminates the “yo-yo effect” of two regulators repeatedly turning on and off as the battery approaches target voltage because the two systems are not working in concert. Useful in applications like multihulls and powerboats with twin propulsion motors, the Centerfielder II acts like a referee, ensuring that both port and starboard charging systems work together, rather than compete, to keep a large house battery efficiently charged.\u003c\/p\u003e\u003cp\u003eThe Centerfielder II is designed to work specifically with \u003ca href=\"https:\/\/enerdrive.com.au\/product\/balmar-max-charge-regulators-mc-614-mc-624\/\"\u003eMC-614\u003c\/a\u003e and \u003ca href=\"https:\/\/enerdrive.com.au\/product\/balmar-max-charge-regulators-mc-614-mc-624\/\"\u003eMC-624\u003c\/a\u003e voltage regulators\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eCenterfielder II: CFII-12\/24\u003c\/strong\u003e, \u003cstrong\u003e\u003cem\u003eBalanced Twin Engine Charging\u003c\/em\u003e\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eBalances Charging in Twin Engine Applications\u003c\/li\u003e\n\u003cli\u003eEliminates Alternator Chatter by Unifying Field Current\u003c\/li\u003e\n\u003cli\u003eFor Use with Max Charge Regulators Only\u003c\/li\u003e\n\u003cli\u003eWorks in Both 12V and 24V Applications\u003c\/li\u003e\n\u003cli\u003eIncludes Upgraded Regulator Power Wires and Fusing\u003c\/li\u003e\n\u003cli\u003eIsolates Alternators and Regulators when only One Engine is Running\u003c\/li\u003e\n\u003cli\u003eCan be Used with the Digital Duo Charge to charge a Second Battery\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eDownloads\u003c\/h3\u003e\u003cul\u003e\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0953\/8237\/2639\/files\/Balmar-Centerfielder-II-Manual_opt.pdf?v=1789531318\" rel=\"noopener\" target=\"_blank\"\u003eBalmar CFII-12\/24 Centerfielder Manual\u003c\/a\u003e\u003c\/li\u003e\u003c\/ul\u003e","brand":"Balmar","offers":[{"title":"Default Title","offer_id":52794694336799,"sku":"B-CFII-12-24","price":594.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/8237\/2639\/files\/BAL.CFII-1224_1200x1200_b15b0743-a2d6-4825-b167-c27391d6ec63.jpg?v=1789528219"},{"product_id":"balmar-mc-612-dual-regulator","title":"Balmar MC-612-Dual Regulator","description":"\u003cp\u003eRegulator, Dual MC-612 Multi-Stage, 12v, w\/Harnesses. For Use with Twin Alternator, Single Engine Applications\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cp\u003eThe Balmar Max Charge MC-612-DUAL is designed for use in single engine \/ dual alternator applications where both alternators are being used to charge the same large battery bank. The MC-612-DUAL provides two field output connectors, two power input connectors and two system ground connections, making it possible to use two standard wiring harnesses when connecting to two alternators.\u003c\/p\u003e\u003cp\u003eThe MC-612-DUAL features user selectable programs for the following battery types: Deep cycle flooded, standard flooded, gel, AGM, spiral wound AGM, and LiFePO4 batteries. The regulator also features a universal default program that’s designed for use in vessels utilizing voltage sensitive halogen equipment\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSKU\u003c\/th\u003e\n\u003cth\u003eB-MC-612-DUAL-H\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\u003ctr\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRegulator, Dual MC-612 Multi-Stage, 12v, w\/Harnesses. For Use with Twin Alternator, Single Engine Applications\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eDownloads\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0953\/8237\/2639\/files\/PDS-MC-612-Dual-H.pdf?v=1789531318\" rel=\"noopener\" target=\"_blank\"\u003eBalmar MC-612-DUAL-H Regulator Manual\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/balmar.net\/balmar-catalog\/\" rel=\"noopener\" target=\"_blank\"\u003eBalmar Catalogue\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Balmar","offers":[{"title":"Default Title","offer_id":52794707738911,"sku":"B-MC-612-DUAL-H","price":803.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/8237\/2639\/files\/MC-612-DUAL-H.png?v=1789528219"}],"url":"https:\/\/www.enerdrive.com.au\/collections\/alternators-regulators.oembed","provider":"Dometic Mobile Power APAC","version":"1.0","type":"link"}