Enerdrive ePOWER Battery Charger Specifications
Model EN31220 EN31240 EN31260 EN32430
Note: Specifications subject to change without notice.
CHARGER OUTPUT
Output Current (Maximum) 20A 40A 60A 30A
OUTPUT VOLTAGE RANGE
Charge 14.2 – 15.5 V 28.4 – 31.0V
Float 13.4 – 13.8 V 26.8 – 27.6V
– Equalize 16.0 V 32.0V
Charging Control Four stages (Bulk/Absorption/Float/Maintenance)
Two stages (Bulk/Absorption)
Constant Power Supply (Program setting)
Priority Battery Bank Charging
DC Output Bank Three (1 fully independent, 2 common with diode isolation)
Selectable Battery Type Gel, AGM, Flooded, Lithium, Program
Standby Current < 2 mA
CHARGER INPUT
AC Input Voltage (Nominal) 90 to 265 VAC
AC Input Operating Range 207-265 Vac (2.0 A Max)90-125 Vac (3.8 A Max) 207-265 Vac (3.8 A Max)90 – 125 Vac (7.7 A Max) 207-265 Vac (5.9 A Max)90-125 Vac (11.3 A Max) 207-265 Vac (5.9 A Max)90-125 Vac (11.3 A Max)
AC Input Frequency Range 47 – 63 Hz
Power Consumption 350W (Full Load) 700W (Full Load) 1050W (Full Load) 1050W (Full Load)
Power Factor Correction Yes
Charger Efficiency > 82%
PROTECTION AND FEATURES
Reverse Polarity Yes, (with user replaceable fuse/s)
Over Charge Yes, unit shutdown
Over Temperature Yes, unit de-rated and shutdown
Output Short Circuit Yes, (with user replaceable fuse/s)
Cooling Forced air ventilation (thermo controlled fan)
Temperature Setting Hot, Normal, Cold (no sensor connected)
Battery Temp Sensor Port RJ12 (standard battery temp. sensor supplied)
DISPLAY
LCD Display (with back light) Charging status, Battery Voltage, Output Current & Fault Codes.
AC INPUT AND DC OUTPUT CONNECTION
AC Input Connection IEC with Supplied 1.2M Power Lead
DC Output Connection Heavy Duty Terminal (3 banks) – Pan Heads 6mm Thread
DC Output Ground Single Heavy Duty Common Ground Stud
ENVIRONMENTAL AND OPERATING TEMPERATURE
Storage Range -40° to 70° C
Operating Range -20° to 60° C
Humidity 5-95%, relative humidity non-condensing
Ingress Protection IP32 (Basic drip proof in vertical orientation)
Base Unit Weight and Dimensions
Weight: (kg) 2.4 2.6 4.0 4.0
Dimension: (mm) L x W x H 295 x 206 x 86 295 x 206 x 86 356 x 206 x 99 356 x 206 x 99
Optional Accessories Remote Digital Display / Enerdrive Part Number EN3REM
Regulatory Compliance Complies with AS/NZS 60335.2.29 Including Australian deviations.
ePOWER Battery Charger Accessories
Enerdrive Part # Description
Note: Specifications subject to change without notice.
EN3REM ePOWER Universal Remote Control Optional Remote Control for ePOWER chargers
EN3TEMP ePOWER Battery Temperature Sensor Replacement Temperature Sensor to Suit ePOWER Chargers