Studer XTM Inverter Charger Specifications
| Model - Description | Xtenda Mobile 1500w / 12v with 70amp Charger & T/Fer Relay | Xtenda Mobile 2000w / 12v with 85amp Charger & T/Fer Relay | Xtenda Mobile 2400w / 24v with 55amp Charger & T/Fer Relay | Xtenda Mobile 3500w / 24v with 75amp Charger & T/Fer Relay | Xtenda Mobile 2600w / 48v with 30amp Charger & T/Fer Relay |
|---|---|---|---|---|---|
| Enerdrive Code | XTM1500-12 | XTM2000-12 | XTM2400-24 | XTM3500-24 | XTM2600-48 |
| Nominal Battery Voltage | 12v | 12v | 24V | 24V | 48V |
| Output Power (continuous) @ 25°C | 1500VA | 2000VA | 2000VA | 3000VA | 2000VA |
| Output Power 30min @ 25°C | 1500VA | 2000VA | 2400VA | 3500VA | 2600VA |
| Peak Output Power (5 Sec's) | 3400VA | 4800VA | 6000VA | 9000VA | 6500VA |
| Smart Boost - PowerShare (30min @ 25°C) | 1500VA | 2000VA | 2400VA | 3500Va | 2600VA |
| Output Voltage | 230VAC | 230VAC | 230VAC | 230VAC | 230VAC |
| OutPut Frequency | 50Hz | ||||
| Output Waveform | Sinewave | ||||
| Peak Efficiency | 93% | 93% | 94% | 94% | 96% |
| No Load Current Draw On - Stand-by | 8 - 1.4W | 10 - 1.4W | 9 - 1.6W | 12 - 1.6W | 10 - 2W |
| Input Voltage Range | 9.5 to 17Vdc | 9.5 to 17Vdc | 19 to 34Vdc | 19 to 34Vdc | 38 to 68Vdc |
| Operating Temperature Range | -20 to 55°C | ||||
| Digital Display | Optional R/C | ||||
| Low Battery Alarm | Fully Programable | ||||
| Low Battery Cutout | Fully Programable | ||||
| Battery Connection | Bolt in Connection | ||||
| Mounting Bracket | Built in | Built in | Built in | Built in | Built in |
| Internal DC Fuse | User Serviceable on DC Conn | User Serviceable on DC Conn | User Serviceable on DC Conn | User Serviceable on DC Conn | User Serviceable on DC Conn |
| Overload and Short Circuit Protection | Automatic disconnection with 3 time restart attempt | ||||
| Overtemp Protection | Acoustic warning before shut off with auto restart + Forced Fan above 55°C | ||||
| Battery charger Output Current | 0 to 70A | 0 to 100A | 0 to 55A | 0 to 90A | 0 to 30A |
| AC Transfer Capability | Yes - 50A/11.5kVA | ||||
| AC Transfer Time | <15ms | ||||
| Absorption Time | All Parameters are configerable by installer to individual requirements - (Bulk Charge Cycle Voltage -Floating Voltage - Equalisation Time - Equalisation Voltage) | ||||
| Dimensions (H x W x D) | 322 x 133 x46.6mm | 322 x 133 x46.6mm | 323 x 133 x46.6mm | 324 x 133 x46.6mm | 325 x 133 x46.6mm |
| IP Rating | IP20 | ||||
| Weight | 15kg | 18.5kg | 16.2kg | 21.2kg | 16.2kg |
| Warranty | 2 year | ||||
| Model - Description | Xtenda Mobile 4000w / 48v with 65amp Charger & T/Fer Relay | Xtenda Series 3000w / 12v with 160amp Charger & T/Fer Relay | Xtenda Series 5000w / 24v with 120amp Charger & T/Fer Relay | Xtenda Series 6000w / 48v with 100amp Charger & T/Fer Relay | Xtenda Series 8000w / 48v with 110amp Charger & T/Fer Relay | |||||
|---|---|---|---|---|---|---|---|---|---|---|
| Enerdrive Code | XTM4000-48 | XTH3000-12 | XTH5000-24 | XTH6000-48 | XTH8000-48 | |||||
| Nominal Battery Voltage | 48V | 12V | 24V | 48V | 48V | |||||
| Output Power (continuous) @ 25°C | 3500VA | 2500VA | 4500VA | 5000VA | 7000VA | |||||
| Output Power 30min @ 25°C | 4000VA | 3000VA | 5000VA | 6000VA | 8000VA | |||||
| Peak Output Power (5 Sec's) | 10500VA | 7500VA | 12000VA | 15000VA | 210 00VA | |||||
| Smart Boost - PowerShare (30min @ 25°C) | 4000VA | 3000VA | 5000VA | 6000VA | 8000VA | |||||
| Output Voltage | 230VAC | 230VAC | 230VAC | 230VAC | 230VAC | |||||
| OutPut Frequency | 50Hz | |||||||||
| Output Waveform | Sinewave | |||||||||
| Peak Efficiency | 96% | 93% | 94% | 96% | 96% | |||||
| No Load Current Draw On - Stand-by | 14 - 2.1W | 14 - 1.4W | 18 - 1.8W | 22 - 2.2W | 30 - 2.4W | |||||
| Input Voltage Range | 39 to 68Vdc | 9.5 to 17Vdc | 19 to 34Vdc | 38 to 68Vdc | 38 to 68Vdc | |||||
| Operating Temperature Range | -20 to 55°C | |||||||||
| Digital Display | Optional R/C | |||||||||
| Low Battery Alarm | Fully Programable | |||||||||
| Low Battery Cutout | Fully Programable | |||||||||
| Battery Connection | Bolt in Connection | |||||||||
| Mounting Bracket | Built in | Ext Mount Brkt | Ext Mount Brkt | Ext Mount Brkt | Ext Mount Brkt | |||||
| Internal DC Fuse | User Serviceable on DC Conn | No - Req Ext | No - Req Ext | No - Req Ext | No - Req Ext | |||||
| Overload and Short Circuit Protection | Automatic disconnection with 3 time restart attempt | |||||||||
| Overtemp Protection | Acoustic warning before shut off with auto restart + Forced Fan above 55°C | |||||||||
| Battery charger Output Current | 0 to 50A | 0 to 160A | 0 to 140A | 0 to 100A | 0 to 120A | |||||
| AC Transfer Capability | Yes - 50A/11.5kVA | |||||||||
| AC Transfer Time | <15ms | |||||||||
| Absorption Time | All Parameters are configerable by installer to individual requirements - (Bulk Charge Cycle Voltage -Floating Voltage - Equalisation Time - Equalisation Voltage) | |||||||||
| Dimensions (H x W x D) | 325 x 133 x46.6mm | 500 x 300 x 230mm | 500 x 300 x 230mm | 500 x 300 x 230mm | 500 x 300 x 230mm | |||||
| IP Rating | IP20 | |||||||||
| Weight | 22.9kg | 34kg | 40kg | 42kg | 46kg | |||||
| Warranty | 2 year | |||||||||
| Optional Accessories | ||||
|---|---|---|---|---|
| Enerdrive Code | RCC-02 | RCC-03 | RCM-10 | BTS-01 |
| Model | Remote Control For Xtenda Series (Surface Mount) | Remote Control For Xtenda Series (Flush Mount) | Remote Command Module (enables remote On / Off control for XTM ONLY) | Battery Temp Sensor (3mtr Cable) |
| Dimensions (H x W x D) | 170 x 168 x 43.5mm | 170 x 168 x 43.5 mm | 45 x 45 x 73mm | |
| Cut Out Dimensions H x W x Intrusion | N/A | 98 x 100 x 43mm | N/A | |
| Display | LCD | LCD | N/A | |
| Warranty | 2 year | |||