Mori Battery Charger Specifications
| SINGLE PHASE | Flooded | Sealed | |||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Model | V | A | Input | Unit Weight Kg | Unit Size L x W x H | 13h - Ah / C5 | 11h - Ah / C5 | 8h - Ah / C5 | 12h - Ah / C5 | ||||
| Min. | Max. | Min. | Max. | Min. | Max. | Min. | Max. | ||||||
| PSW2460 | 24 | 60 | 15A | 3.9 | 330x175x100h | 180 | 720 | 180 | 600 | 180 | 360 | 180 | 600 |
| PSW2490PFC | 24 | 90 | 15A | 7.2 | 430x280x105h | 270 | 1080 | 270 | 900 | 270 | 540 | 270 | 900 |
| PSW3640 | 36 | 40 | 15A | 3.9 | 330x175x100h | 160 | 480 | 160 | 420 | 160 | 240 | 160 | 420 |
| PSW3660PFC | 36 | 60 | 15A | 7.2 | 430x280x105h | 180 | 720 | 180 | 600 | 180 | 360 | 180 | 600 |
| PSW4830 | 48 | 30 | 15A | 3.9 | 330x175x100h | 120 | 360 | 120 | 300 | 120 | 180 | 120 | 300 |
| PSW4845PFC | 48 | 45 | 15A | 7.2 | 430x280x105h | 160 | 540 | 160 | 480 | 160 | 270 | 160 | 480 |
| PSW4865PFC | 48 | 65 | 20A | 7.2 | 430x280x105h | 180 | 780 | 180 | 660 | 180 | 420 | 180 | 660 |
| MAINS VOLTAGE | FREQUENCY | EFFICIENCY | ROOM WORKING TEMPERATURE | MIN. BATTERY VOLTAGE TO LET THE CHARGE CYCLE START | CHARGE PROFILE FOR FLOODED BATTERIES | CHARGE PROFILE FOR SEALED BATTERIES | MAINS CABLE | OUTPUT CABLES |
|---|---|---|---|---|---|---|---|---|
| min.185V - Max.265V | 47 / 62 Hz | >85% | 0˚C / + 40˚C | 1.00 V/cel | IWoP | IUoP | 1.0 m | 2.5 m |
| THREE PHASE | Flooded | Sealed | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Model | V | A | Unit Weight Kg | Unit Size L x W x H | 13h - Ah / C5 | 11h - Ah / C5 | 8h - Ah / C5 | 12h - Ah / C5 | ||||
| Min. | Max. | Min. | Max. | Min. | Max. | Min. | Max. | |||||
| PSW24120 | 24 | 120 | 10.9 | 540x340x130h | 360 | 1400 | 360 | 1200 | 360 | 720 | 360 | 1200 |
| PSW24240 | 24 | 240 | 21.5 | 590x435x265h | 720 | 2800 | 720 | 2400 | 720 | 1400 | 720 | 2400 |
| PSW4880 | 48 | 80 | 11.3 | 540x340x130h | 300 | 960 | 300 | 840 | 300 | 480 | 300 | 840 |
| PSW48120 | 48 | 120 | 11.5 | 540x340x130h | 360 | 1400 | 360 | 1200 | 360 | 720 | 360 | 1200 |
| MAINS VOLTAGE | FREQUENCY | EFFICIENCY | ROOM WORKING TEMPERATURE | MIN. BATTERY VOLTAGE TO LET THE CHARGE CYCLE START | CHARGE PROFILE FOR FLOODED BATTERIES | CHARGE PROFILE FOR SEALED BATTERIES | MAINS CABLE | OUTPUT CABLES |
|---|---|---|---|---|---|---|---|---|
| min.340V - Max.460V | 47 / 62 Hz | >90% | 0˚C / + 40˚C | 1.00 Volt / cel | IWoP | IUoP | 1.0 m | 2.5 m |