Xantrex™ TrueCharge™ 2

Product Info

In addition to meeting global safety and regulatory standards, TRUECHARGE2 Battery Chargers feature low electrical interference and superior, efficient, power factor corrected multistage charging. TRUECHARGE2 Battery Chargers can be mounted virtually anywhere, given their unique drip-proof design. With certified ignition protection, even a gasoline engine room is an alternative for installation*. Trouble-free installation is ensured with easy-to-access AC and DC wiring compartments and reverse-polarity battery protection.

Designed primarily for marine and commercial applications worldwide, TRUECHARGE2 Battery Chargers are unmatched for reliability. Available in two 12-volt models, they are versatile enough to be used in a wide variety of conditions and locations. Auto-ranging AC input voltage capability (90 - 265 volts AC) makes traveling abroad and handling poor-quality power a breeze. The easy-to-read display can be augmented with an optional remote panel.

Performance Features

12-volt models available in 20 A and 40 A
Microprocessor-controlled, multistage charging algorithms
Settings for two and three-stage charging
Settings for flooded, gel, AGM or lead-calcium batteries
Auto-ranging universal input voltage (90-265 Vac, 47-63 Hz) is also compatible with a generator or other low-quality power sources
Temperature-compensated charging
Power factor corrected for efficient charging
Battery-equalization feature
Ability to charge ‘dead’ batteries
Battery temperature sensor available (Part #808-0232-01)
Optional remote display includes a maximum charger output control (Part #808-8040-00)
Protection Features

Reverse battery polarity protection
Drip-proof design
Over and under-temperature protection
DC over-voltage protection
Battery overcharging protection
Ignition protection

Three-Stage Charging

Multistage charging ensures batteries receive optimum charging, but with minimal wear and tear, regulating the voltage and current delivered to the batteries in three automatic stages:

  • Bulk: Replaces 70-80% of the battery’s state-of-charge at the fastest possible rate.
  • Absorption: Replenishes the remaining 20-30% of charge, bringing the battery to a full charge at a slow, safe rate.
  • Float: Voltage is reduced and held constant in order to prevent damage and maintain batteries at a full charge.

Power Factor Corrected (PFC)

Less shorepower is required for charging batteries, freeing up more usable AC power for running electrical devices and appliances and reducing the likelihood of tripping shorepower breakers.

* Xantrex recommends, however, that it is safest not to install electrical equipment in these areas.

 

Electrical Specifications (@ 25°C unless otherwise noted)
Models TRUECHARGE2 20 / 40 TRUECHARGE2 60
Output current (nominal) 20 A / 40 A 60 A
Output voltage (nominal, depending on settings)
Charge 14.2 - 15.5 Vdc 14.2 - 15.5 Vdc
Float 13.4 - 13.8 Vdc 13.4 - 13.8 Vdc
Equalize 16 Vdc 16 Vdc
DC output connections Three Three
AC input voltage (*1)

90-265 Vac 47-63 Hz

120 Vac, 230 Vac, 240 Vac nominal

90-265 Vac 47-63 Hz

120 Vac, 230 Vac, 240 Vac nominal

Temperature compensation Three settings or optional remote battery temperature sensor
Charger efficiency > 80% > 80%
Battery type Gel, Flooded, AGM and Pb-Ca Gel, Flooded, AGM and Pb-Ca
Minimum recommended battery bank size 40 Ah for 20 A / 80 Ah for 40 A 120 Ah for 60 A

 

General Specifications
Models TRUECHARGE2 20 / 40 TRUECHARGE2 60
Operating temperature (*2) 0 to 65°C 0 to 65°C
Storage temperature -40 to 80°C -40 to 80°C
Battery connection

Three positive terminals

One negative terminal

Three positive terminals

One negative terminal

Dimensions (H x W x L) 70 × 170 × 250mm 90 x 170 x 340 mm
Weight 2.2 kg 4.5 kg
Warranty Two year Two year
Part Numbers

804-1220 / 804-1240

804-1260

 

Accessories
Remote panel 808-8040-00
Battery temperature sensor 808-0232-01

 

Regulatory Compliance
CSA E60335-2-29, UL1564, and UL1236 including the Marine Supplement, drip test, and Ignition Protection ratings. CE Marked for the Low Voltage Directive (safety) and the EMC Directive. Complies with IEC 60335-2-29 including Australian deviations. Ingress protection rating IP32 per EN/IEC 60529. Complies with FCC Part 15B and Industry Canada ICES-003 Class B emissions limits. Complies with ABYC A-31

 

(*1) 90 - 104 Vac ± 4 Vac output de-rated to 80% of full load current

(*2) For 20A and 40A charger, output current derates above 50°C. For 60 A charger, output current derates above 40°C. Highly Accelerated Life Tested (HALT) to -20°C.

Note: Specifications subject to change without notice.